Gemini©
Stainless Steel
Double Cylinder
Air Actuated Valves
Model 412 (Left) and Model 411 (Right)
1/2 Second Response Time @ 700 PSI!
These valves are great for mono and bi-propellant applications.
They're almost flightweight but are more suited for test stand work.
$95 per Valve
Features;
Compact, Lightweight Aluminum Body and Bracket featuring both Internal
and External Teflon-Impregnated Hard Anodized Surfaces
Stainless Steel External Trim & Viton O-rings Standard
Direct Valve Stem Coupling to Actuator Shaft Minimizes Backlash
Manual Override
Easily Visible Open / Shut Position Read Out
Click to Enlarge Chart

Gemini© Pneumatically Actuated Ball Valves offer a unique combination
of three elements required for long trouble free life - a premium quality
ball valve, a quality actuator designed to meet the torque requirements
of the valve and a mounting bracket and connection which assures alignment
and rigidity.
Gemini© Pneumatic Actuatorís simple rack and pinion design, made
possible through unique manufacturing techniques, results in a bar stock
actuator which is compact, efficient and trouble free.
All actuators are factory lubricated so that there is no need for lubricated
air.
All threaded bolt holes in the aluminum components have self locking
stainless steel inserts to assure strong, positive fastening.
Gemini© Actuator mounting is the key element of our pneumatically
actuated ball valves. A good valve and actuator, poorly mounted, results
in an inferior actuated valve. The Gemini coupling eliminates this possibility
with the ëmissing linkí i.e., the actuator shaft is precisely coupled directly
to the valve stem, thereby eliminating misalignment and backlash often
found with the commonly used torque and groove connecting linkage. The
valve stem nut is fixed within the actuator shaft These features, combined
with a rigid mounting bracket, result in a pneumatically actuated ball
valve which minimizes backlash, assures optimum stem seal life and prevents
any possibility of stem nut back off.
Pilot valves are available from other sources, please contact us for
more information.
Specifications;
Temperature
Pneumatic Actuators are designed to operate in ambient temperatures
between -20 F (-28.0 C) and +350 F (+175 C). Care must be taken to assure
that the moisture content of the air supply is sufficiently low to prevent
icing within the actuator.
Air Supply
Double-Acting model A412D require 50 - 125 psi, A411D model require
75 - 125 psi air supply. Sufficient air delivery must be available at
the actuator to ensure dependable operation. The following precautions
should be observed:
Air supply should be clean and dry. When dirty or wet air is a problem;
a filter / separator should be specified; these units are most effective
when installed as closely as possible to the actuator. A filter, when used,
should permit a minimum flow of 4 scfm at an upstream pressure of 60 psi.
Eliminate severe restrictions to air flow (certain solenoid valves &
fittings). The most restricted passage must have an area no smaller than
.003" square, the area of 1/16" diameter orifice. If more than a single
actuator is to be supplied by an individual pilot, the minimum passage
requirement applies per actuator.
Tubing:
For short runs up to 5 feet 5/32" I.D. is suitable, 1/4" I.D. will
serve up to 30 feet. For longer runs, use 3/8" I.D. or larger.
Back to Plumbing Index |